Model: |
YX-3KS-1-1 |
YX-3KS-2-1 |
YX-3KS-1-2 |
YX-3KS-2-2 |
Continuous Power: |
3000W |
Peak Power: |
6000W |
DC Voltage: |
DC12V |
DC24V |
DC12V |
DC24V |
AC Voltage: |
100VAC or 110VAC or 120VAC ± 3V |
220VAC or 230VAC or 240VAC ± 3V |
No Load Current Draws: |
1.2A |
0.5A |
1.2A |
0.5A |
DC Voltage Range: |
10-15.5V |
20-31V |
10-15.5V |
20-31V |
Low Voltage Alarm: |
Lo0:10.5V |
11V±0.3V |
Lo0:21V |
22V±0.3V |
Lo0:10.5V |
11V±0.3V |
Lo0:21V |
22V±0.3V |
Lo1:10.8V |
11.3V±0.3V |
Lo1:21.6V |
22.6V±0.3V |
Lo1:10.8V |
11.3V±0.3V |
Lo1:21.6V |
22.6V±0.3V |
Lo2:11.3V |
11.8V±0.3V |
Lo2:22.6V |
23.6V±0.3V |
Lo2:11.3V |
11.8V±0.3V |
Lo2:22.6V |
23.6V±0.3V |
Low Voltage Shut Down: |
Lo0:10.5V |
10.5V±0.3V |
Lo0:21V |
21V±0.3V |
Lo0:10.5V |
10.5V±0.3V |
Lo0:21V |
21V±0.3V |
Lo1:10.8V |
10.8V±0.3V |
Lo1:21.6V |
21.6V±0.3V |
Lo1:10.8V |
10.8V±0.3V |
Lo1:21.6V |
21.6V±0.3V |
Lo2:11.3V |
11.3V±0.3V |
Lo2:22.6V |
22.6V±0.3V |
Lo2:11.3V |
11.3V±0.3V |
Lo2:22.6V |
22.6V±0.3V |
Low Voltage Alarm Recovery: |
Lo0:10.5V |
11.3V±0.3V |
Lo0:21V |
22.6V±0.3V |
Lo0:10.5V |
11.3V±0.3V |
Lo0:21V |
22.6V±0.3V |
Lo1:10.8V |
11.6V±0.3V |
Lo1:21.6V |
23.2V±0.3V |
Lo1:10.8V |
11.6V±0.3V |
Lo1:21.6V |
23.2V±0.3V |
Lo2:11.3V |
12.1V±0.3V |
Lo2:22.6V |
24.2V±0.3V |
Lo2:11.3V |
12.1V±0.3V |
Lo2:22.6V |
24.2V±0.3V |
Low Voltage Protection Recovery: |
Lo0:10.5V |
12V±0.3V |
Lo0:21V |
24V±0.3V |
Lo0:10.5V |
12V±0.3V |
Lo0:21V |
24V±0.3V |
Lo1:10.8V |
12.3V±0.3V |
Lo1:21.6V |
24.6V±0.3V |
Lo1:10.8V |
12.3V±0.3V |
Lo1:21.6V |
24.6V±0.3V |
Lo2:11.3V |
12.8V±0.3V |
Lo2:22.6V |
25.6V±0.3V |
Lo2:11.3V |
12.8V±0.3V |
Lo2:22.6V |
25.6V±0.3V |
Over Voltage Shut Down: |
15.7V±0.3V |
31.5V±0.3V |
15.7V±0.3V |
31.5V±0.3V |
Over Voltage Recovery: |
15.3V±0.3V |
30.6V±0.3V |
15.3V±0.3V |
30.6V±0.3V |
Frequency: |
50HZ ± 0.5HZ or 60HZ ± 0.5HZ |
Output Waveform: |
Pure Sine Wave |
AC Regulation: |
THD<3% (Linear load) |
Output Efficiency: |
12V: up to 91%; 24V:up to 92% |
Remote Control (Optional): |
Cable length: 15m is available. |
Power-Saving Mode: |
The power saving mode will be activated when the output power is less than 5W. When output power is more than 10W, the inverter will automatically return to normal status. |
Ignition Function: |
Connect vehicles battery (or connect positive pole of vehicles' STARTER). The inverters start simultaneously When the vehicles start; The inverters will shut down meantime when the vehicles shut down. |
Protection Function: |
Low voltage alarm |
code: F05 |
Buzzer sounds and fault light turns red |
Low voltage shutdown |
code: F01 |
Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) |
Over input voltage protection |
code: F02 |
Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) |
Over load alarm |
code: F06 |
Buzzer sounds and fault light turns red when output power is overloaded around 110%. But the BUZZ and F06 code will not occured when the output power drop to a normal level within 20ms. |
Over load protection |
code: F03 |
The inverter shutdown when output power is overloaded around 120%, it need to be recovered by hand. |
Over temperature alarm |
code: F07 |
Buzzer sounds and fault light turns red when the inverter's internal temperature is higher than the limit value (90±5ºC). |
Over temperature protection |
code: F04 |
The inverter will automatically return to normal status when the internal temperature drops to 80±5ºC. |
|
code: F08 |
The display will show the code F08 when the thermostat in the inverters is broken |
Short circuit protection |
code: F03 |
Recover by hand |
Reverse polarity protection |
|
Built-in fuse |
AC input overload protection |
code: F09 |
The fan will start to work when the relay temperature is up to 60±5ºC; but it will stop to work when the relay temperature drops to 50±5ºC. The unit will alarm, and no AC output when relay temperature is up to 75±5ºC; But it will auto recover when the relay temperature drops to normal value. |
Fuse: |
Internal |
USB port |
5V, 2.1A |
Working Temperature: |
-10°C--+50°C |
Product Size |
436×197×82mm |
Storage Temperature: |
-30°C--+70°C |
Packing Size |
48×26×14cm |
Warranty: |
18 months |
N.W. / G.W. (KG) |
5.7KG/6.5KG |
Start: |
Bipolar soft-start |
Quantity / Carton |
2pcs |
Cooling Way: |
Intelligent cooling fan |
Carton Size |
50×26.5×30cm |
Certification: |
CE, E-mark, FCC |
Carton Weight |
14.0KG |