Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | ISO9001, RoHS, CE, SAA, E-MARK, LVD, EMC |
Still deciding? Get samples of US$ 100/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1500W Pure Sine Wave Power Inverter with bypass
Features:
What you will get
A 1500w pure sine inverter with transfer switch and a user manual.
Model | YX-1.5KUS-1-1 | YX-1.5KUS-2-1 | YX-1.5KUS-1-2 | YX-1.5KUS-2-2 | |||||
Continuous Power | 1500W | ||||||||
Peak Power | 3000W | ||||||||
DC Voltage | DC12V | DC24V | DC12V | DC24V | |||||
AC Voltage | 100VAC or 110VAC or 120VAC ± 5% (can be set by user ) | 220VAC or 230VAC or 240VAC ± 5% (can be set by user ) | |||||||
No Load Current Draws | 1A | 0.5A | 1A | 0.5A | |||||
Frequency | 50Hz ± 0.5Hz or 60Hz ± 0.5Hz ( Can be set by user ) | ||||||||
Output Waveform | Pure Sine Wave | ||||||||
AC Regulation | THD<3% (Linear load) | ||||||||
Output Efficiency | up to 91% | ||||||||
Max AC Input Current | 12.5A | 6.5A | |||||||
Transfer relay rating | 16A | ||||||||
Transfer time AC to inverter and inverter to AC | Less than 30ms | ||||||||
AC Output Socket | EU / AU: 16A max; UK / US: 15A max | ||||||||
Low Voltage setting | The low voltage has four levels (Lo0, Lo1, Lo2, Lo3) to be set, it can meet different battery type. | ||||||||
Remote Control (Optional) | Remote control port is RJ12. Cable length: 15m is available. | ||||||||
Power-Saving mode | The power saving mode will be activated when the output power is less than 15W. When output power is more than 20W, the inverter will automatically return to normal status. | ||||||||
Ignition Function | The Ignition Start Port is used for connecting to the ignition start signal from vehicles to control the operation of the inverter. | ||||||||
DC Input Protection | |||||||||
DC Voltage Range | 10-15.5V | 20-31V | |||||||
Low Voltage Alarm | Lo0 | 11V | Lo0 | 22V | |||||
Lo1 | 11.3V | Lo1 | 22.6V | ||||||
Lo2 | 11.8V | Lo2 | 23.6V | ||||||
Lo3 | 12.3V | Lo3 | 24.6V | ||||||
Low Voltage Shut Down | Lo0 | 10.5V | Lo0 | 21V | |||||
Lo1 | 10.8V | Lo1 | 21.6V | ||||||
Lo2 | 11.3V | Lo2 | 22.6V | ||||||
Lo3 | 11.8V | Lo3 | 23.6V | ||||||
Low Voltage Alarm Recovery | Lo0 | 11.3V | Lo0 | 22.6V | |||||
Lo1 | 11.6V | Lo1 | 23.2V | ||||||
Lo2 | 12.1V | Lo2 | 24.2V | ||||||
Lo3 | 12.6V | Lo3 | 25.2V | ||||||
Low Voltage Protection Recovery | Lo0 | 12V | Lo0 | 24V | |||||
Lo1 | 12.3V | Lo1 | 24.6V | ||||||
Lo2 | 12.8V | Lo2 | 25.6V | ||||||
Lo3 | 12.8V | Lo3 | 25.6V | ||||||
Over Voltage Shut Down | 15.7V | 31.5V | 15.7V | 31.5V | |||||
Over Voltage Recovery | 15.3V | 29.5V | 15.3V | 29.5V | |||||
Protection Function | |||||||||
Low voltage alarm | code: F05 | Buzzer sounds and fault light turns red | |||||||
Low voltage shutdown | code: F01 | Recover manually after the inverter shutdown. (The inverter will auto recover when the battery voltage goes back to a normal level within 20s.) | |||||||
Over input voltage protection | code: F02 | Recover manually after the inverter shutdown. (The inverter will auto recover when the battery voltage goes back to a normal level within 20s.) | |||||||
Over load alarm | code: F06 | Buzzer sounds and fault light turns red when output power is overloaded around 110%. But the BUZZ and F06 code will not occur when the output power drops to a normal level within 20s. | |||||||
Over load protection | code: F03 | The inverter shutdown when output power is overloaded around 120%, it needs to be recovered manually. | |||||||
Over temperature alarm | code: F07 | Buzzer sounds and fault light turns red when the inverter's internal temperature is higher than the limit value (90±5ºC). | |||||||
Over temperature protection | code: F04 | The inverter will automatically return to normal status when the internal temperature drops to 80±5ºC. | |||||||
code: F08 | The display will show the code F08 when the thermostats in the inverter is broken. | ||||||||
Short circuit protection | code: F03 | Manual recovery | |||||||
Reverse polarity protection | Built-in fuse | ||||||||
AC input overload protection | code: F09 | The fan will start to work when the relay temperature is up to 60±5ºC; but it will stop working when the relay temperature drops to 50±5ºC. The unit will alarm and no AC output when relay temperature is up to 75±5ºC; but it will auto recover when the relay temperature drops to normal value. | |||||||
Fuse | Internal | USB port | 5V, 2.1A | ||||||
Working Temperature | -10°C--+50°C | Product Size | 330x150x78mm | ||||||
Storage Temperature | -30°C--+70°C | Packing Size | 40.5x22x13.5cm | ||||||
Warranty | 18 months | N.W. / G.W. (KG) | 2.6KG/3.2KG | ||||||
Start | Bipolar soft-start | Quantity / Carton | 6pcs | ||||||
Cooling Way | Variable speed cooling fan | Carton Size | 45x42x43cm | ||||||
Certification | CE (LVD EMC), E-mark, FCC | Carton Weight | 20.0KG |