Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | ISO9001, RoHS, CE, SAA, FCC and E-MARK |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATIONS | 12V model | 24V model | 48V model | 12V model | 24V model | 48V model |
120V model | 230V model | |||||
Inverter | ||||||
Continuous AC Output Power | 2000W | |||||
AC Output Current | 16.7A max | 8.7A max | ||||
AC Surge Power (Peak) | 4000W | |||||
AC Output Voltage/Frequency | 110-130 VAC / 60 Hz | 220-240 VAC / 50 Hz | ||||
AC Output Waveform(THD) | 5% max ,2.5% typical | |||||
Nominal DC Input Voltage | 12.5 VDC | 25 VDC | 50 VDC | 12.5 VDC | 25 VDC | 50 VDC |
DC Input Voltage operating range | 10.5 - 16.0 VDC | 21 - 32 VDC | 42 - 63 VDC | 10.5 - 16.0 VDC | 21 - 32 VDC | 42 - 63 VDC |
Efficiency | 90% typical | 94% typical | 90% typical | 94% typical | ||
AC Transfer Switch | ||||||
Nominal AC transfer time - utility to inverter | <30ms (delayed as required by voltage decay of active load) | |||||
Nominal AC transfer time - inverter to utility | <20ms | |||||
Transfer Relay Rating | 30A | 16A | ||||
AC Input Source Setting | 15, 20, 30A | 10, 13, 16A | ||||
AC Output Port 1 (AC Socket) | GFCI(20A) | EU: CEE 7/4 (16A) | ||||
UK: BS1363 (13A) | ||||||
AU: AS/NZS 3112 (10A) | ||||||
AC Output Port 2 (Hard Wire Connector) | 30A max | 16A max | ||||
Display | ||||||
Display Panel Port | RJ12 | |||||
Inverter Mode | Input Voltage, Output Power,Output Voltage | |||||
Charger Mode | Status & Battery voltage,Input Power,Current | |||||
CANBUS Control | By CANBUS | |||||
Remote Panel | By Remote | |||||
Charger | ||||||
Charger input operating range (full power) | 95-135Vac (105-130Vac) | 190-270 Vac (210-260Vac) | ||||
Charging Voltage Range | 13.5 - 14.8 VDC | 27-29.6V | 54-59.2V | 13.5 - 14.8 VDC | 27-29.6V | 54-59.2V |
Charger Current (max) | 80A | 40A | 30A | 80A | 40A | 30A |
Charger Current Setting | 10-80A | 5-40A | 5-30A | 10-80A | 5-40A | 5-30A |
Battery Type | Gel, Flooded, AGM, Lithium, use, Power Supply | |||||
Charge Control | Bulk / Absorption / Float / Recharge | |||||
Maintenance Recharge Cycle | 7 days | |||||
Efficiency | 90% typical | 93% typical | 91% typical | 93% typical | ||
Safety and Environmental | ||||||
Approval | cETLus | CE | ||||
Safety | UL 458, CSA C22.2 No. 107.2-01 |
EN 60204-1 & IEC 61558-2-16 | ||||
EMC | FCC Part 15 Class B | EN 62040-2 Category C2 | ||||
Operating Temperature | 0°C to 50°C | |||||
Storage Temperature | -20°C to 60°C (-4°F to 140°F) | |||||
Relative Humidity | 5-90% noncondensing | |||||
Operating Altitude | Up to 9,843ft (3000m) above sea level | |||||
Weights and Dimensions | ||||||
Weights | 5.9kg | |||||
Dimensions L X W X H | 387.9mm X 287mm X 110mm |