Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | ISO9001, RoHS, CE, E-MARK, FCC |
Still deciding? Get samples of US$ 120/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model: | YX-1.5KUS-1-1 | YX-1.5KUS-2-1 | YX-1.5KUS-1-2 | YX-1.5KUS-2-2 | ||||
Continuous Power: | 1500W | |||||||
Peak Power: | 2900W | |||||||
DC Voltage: | DC12V | DC24V | DC12V | DC24V | ||||
AC Voltage: | 100VAC or 110VAC or 120VAC ± 3V | 220VAC or 230VAC or 240VAC ± 3V | ||||||
No Load Current Draws: | 1A | 0.5A | 1A | 0.5A | ||||
Max AC Input Current: | 12.5A | 6.5A | ||||||
DC Voltage Range: | 10-15.5V | 20-31V | 10-15.5V | 20-31V | ||||
Low Voltage Alarm: | Lo0:10.5V | 11V±0.3V | Lo0:21V | 22V±0.3V | Lo0:10.5V | 11V±0.3V | Lo0:21V | 22V±0.3V |
Lo1:10.8V | 11.3V±0.3V | Lo1:21.6V | 22.6V±0.3V | Lo1:10.8V | 11.3V±0.3V | Lo1:21.6V | 22.6V±0.3V | |
Lo2:11.3V | 11.8V±0.3V | Lo2:22.6V | 23.6V±0.3V | Lo2:11.3V | 11.8V±0.3V | Lo2:22.6V | 23.6V±0.3V | |
Low Voltage Shut Down: | Lo0:10.5V | 10.5V±0.3V | Lo0:21V | 21V±0.3V | Lo0:10.5V | 10.5V±0.3V | Lo0:21V | 21V±0.3V |
Lo1:10.8V | 10.8V±0.3V | Lo1:21.6V | 21.6V±0.3V | Lo1:10.8V | 10.8V±0.3V | Lo1:21.6V | 21.6V±0.3V | |
Lo2:11.3V | 11.3V±0.3V | Lo2:22.6V | 22.6V±0.3V | Lo2:11.3V | 11.3V±0.3V | Lo2:22.6V | 22.6V±0.3V | |
Low Voltage Alarm Recovery: | Lo0:10.5V | 11.3V±0.3V | Lo0:21V | 22.6V±0.3V | Lo0:10.5V | 11.3V±0.3V | Lo0:21V | 22.6V±0.3V |
Lo1:10.8V | 11.6V±0.3V | Lo1:21.6V | 23.2V±0.3V | Lo1:10.8V | 11.6V±0.3V | Lo1:21.6V | 23.2V±0.3V | |
Lo2:11.3V | 12.1V±0.3V | Lo2:22.6V | 24.2V±0.3V | Lo2:11.3V | 12.1V±0.3V | Lo2:22.6V | 24.2V±0.3V | |
Low Voltage Protection Recovery: | Lo0:10.5V | 12V±0.3V | Lo0:21V | 24V±0.3V | Lo0:10.5V | 12V±0.3V | Lo0:21V | 24V±0.3V |
Lo1:10.8V | 12.3V±0.3V | Lo1:21.6V | 24.6V±0.3V | Lo1:10.8V | 12.3V±0.3V | Lo1:21.6V | 24.6V±0.3V | |
Lo2:11.3V | 12.8V±0.3V | Lo2:22.6V | 25.6V±0.3V | Lo2:11.3V | 12.8V±0.3V | Lo2:22.6V | 25.6V±0.3V | |
Over Voltage Shut Down: | 15.7V±0.3V | 31.5V±0.3V | 15.7V±0.3V | 31.5V±0.3V | ||||
Over Voltage Recovery: | 15.3V±0.3V | 30.6V±0.3V | 15.3V±0.3V | 30.6V±0.3V | ||||
Frequency: | 50HZ ± 0.5HZ or 60HZ ± 0.5HZ | |||||||
Output Waveform: | Pure Sine Wave | |||||||
AC Regulation | THD<3% (Linear load) | |||||||
Output Efficiency: | Up to 90% | |||||||
Transfer relay Rating: | 16A | |||||||
Transfer time AC to inverter and inverter to AC: | Less than 30ms | |||||||
Remote Control: | Cable length: 5m cables | |||||||
Power-Saving Mode: | The power saving mode will be activated when the output power is less than 5W. When output power is more than 10W, the inverter will automatically return to normal status. | |||||||
Ignition Function: | Connect vehicles battery (or connect positive pole of vehicles' STARTER). The inverters start simultaneously When the vehicles start; The inverters will shut down meantime when the vehicles shut down. | |||||||
Protection Function: | Low voltage alarm | code: F05 | Buzzer sounds and fault light turns red | |||||
Low voltage shutdown | code: F01 | Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) | ||||||
Over input voltage protection | code: F02 | Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) | ||||||
Over load alarm | code: F06 | Buzzer sounds and fault light turns red when output power is overloaded around 110%. But the BUZZ and F06 code will not occured when the output power drop to a normal level within 20ms. | ||||||
Over load protection | code: F03 | The inverter shutdown when output power is overloaded around 120%, it need to be recovered by hand. | ||||||
Over temperature alarm | code: F07 | Buzzer sounds and fault light turns red when the inverter's internal temperature is higher than the limit value (90±5ºC). | ||||||
Over temperature protection | code: F04 | The inverter will automatically return to normal status when the internal temperature drops to 80±5ºC. | ||||||
Short circuit protection | code: F03 | Recover by hand | ||||||
Reverse polarity protection | Built-in fuse | |||||||
AC input overload protection | code: F09 | The fan will start to work when the relay temperature is up to 60±5ºC; but it will stop to work when the relay temperature drops to 50±5ºC. The unit will alarm, and no AC output when relay temperature is up to 75±5ºC; But it will auto recover when the relay temperature drops to normal value. | ||||||
Fuse: | Internal | USB port | 5V, 2.1A | |||||
Working Temperature: | -10°C--+50°C | Product Size | 355×180×88mm | |||||
Storage Temperature: | -30°C--+70°C | Packing Size | 40×23×15.5cm | |||||
Warranty: | 18 months | N.W. / G.W. (KG) | 2.7KG/3.5KG | |||||
Start: | Bipolar soft-start | Quantity / Carton | 6pcs | |||||
Cooling Way: | Intelligent cooling fan | Carton Size | 47×41×48cm | |||||
Certification: | CE, E-mark, FCC | Carton Weight | 22.0KG |