Model | YX-1KUS-1-1 | YX-1KUS-2-1 | YX-1KUS-1-2 | YX-1KUS-2-2 | |||||
Continuous Power | 1000W | ||||||||
Peak Power | 2000W | ||||||||
DC Voltage | DC12V | DC24V | DC12V | DC24V | |||||
AC Voltage | 100VAC or 110VAC or 120VAC ± 3V | 220VAC or 230VAC or 240VAC ± 3V | |||||||
No Load Current Draws | 1A | 0.5A | 1A | 0.5A | |||||
Max AC Input Current | 8.5A | 4.5A | |||||||
DC Voltage Range | 10-15.5V | 20-31V | 10-15.5V | 20-31V | |||||
Low Voltage Alarm | Lo0:10.5V | 11V±0.3V | Lo0:21V | 22V±0.3V | Lo0:10.5V | 11V±0.3V | Lo0:21V | 22V±0.3V | |
Lo1:10.8V | 11.3V±0.3V | Lo1:21.6V | 22.6V±0.3V | Lo1:10.8V | 11.3V±0.3V | Lo1:21.6V | 22.6V±0.3V | ||
Lo2:11.3V | 11.8V±0.3V | Lo2:22.6V | 23.6V±0.3V | Lo2:11.3V | 11.8V±0.3V | Lo2:22.6V | 23.6V±0.3V | ||
Low Voltage Shut Down | Lo0:10.5V | 10.5V±0.3V | Lo0:21V | 21V±0.3V | Lo0:10.5V | 10.5V±0.3V | Lo0:21V | 21V±0.3V | |
Lo1:10.8V | 10.8V±0.3V | Lo1:21.6V | 21.6V±0.3V | Lo1:10.8V | 10.8V±0.3V | Lo1:21.6V | 21.6V±0.3V | ||
Lo2:11.3V | 11.3V±0.3V | Lo2:22.6V | 22.6V±0.3V | Lo2:11.3V | 11.3V±0.3V | Lo2:22.6V | 22.6V±0.3V | ||
Low Voltage Alarm Recovery | Lo0:10.5V | 11.3V±0.3V | Lo0:21V | 22.6V±0.3V | Lo0:10.5V | 11.3V±0.3V | Lo0:21V | 22.6V±0.3V | |
Lo1:10.8V | 11.6V±0.3V | Lo1:21.6V | 23.2V±0.3V | Lo1:10.8V | 11.6V±0.3V | Lo1:21.6V | 23.2V±0.3V | ||
Lo2:11.3V | 12.1V±0.3V | Lo2:22.6V | 24.2V±0.3V | Lo2:11.3V | 12.1V±0.3V | Lo2:22.6V | 24.2V±0.3V | ||
Low Voltage Protection Recovery | Lo0:10.5V | 12V±0.3V | Lo0:21V | 24V±0.3V | Lo0:10.5V | 12V±0.3V | Lo0:21V | 24V±0.3V | |
Lo1:10.8V | 12.3V±0.3V | Lo1:21.6V | 24.6V±0.3V | Lo1:10.8V | 12.3V±0.3V | Lo1:21.6V | 24.6V±0.3V | ||
Lo2:11.3V | 12.8V±0.3V | Lo2:22.6V | 25.6V±0.3V | Lo2:11.3V | 12.8V±0.3V | Lo2:22.6V | 25.6V±0.3V | ||
Over Voltage Shut Down | 15.7V±0.3V | 31.5V±0.5V | 15.7V±0.3V | 31.5V±0.5V | |||||
Over Voltage Recovery | 15.3V±0.3V | 29.5V±0.5V | 15.3V±0.3V | 29.5V±0.5V | |||||
Frequency | 50HZ ± 0.5HZ or 60HZ ± 0.5HZ | ||||||||
Output Waveform | Pure Sine Wave | ||||||||
AC Regulation | THD<3% (Linear load) | ||||||||
Output Efficiency | up to 91% | ||||||||
Transfer relay rating | 16A | ||||||||
Transfer time AC to inverter and inverter to AC | Less than 30ms | ||||||||
Remote Control (Optional) | Cable length: 15m is available. | ||||||||
Power-Saving mode | The power saving mode will be activated when the output power is less than 5W. When output power is more than 10W, the inverter will automatically return to normal status. | ||||||||
Ignition Function | Connect vehicles battery (or connect positive pole of vehicles' STARTER). The inverters start simultaneously When the vehicles start; The inverters will shut down meantime when the vehicles shut down. | ||||||||
Protection Function | Low voltage alarm | code: F05 | Buzzer sounds and fault light turns red | ||||||
Low voltage shutdown | code: F01 | Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) | |||||||
Over input voltage protection | code: F02 | Recover by hand after the inverter shutdown. (the inverter will auto recover when the battery voltage go back to a normal level within 20ms.) | |||||||
over load alarm | code: F06 | Buzzer sounds and fault light turns red when output power is overloaded around 110%. But the BUZZ and F06 code will not occured when the output power drop to a normal level within 20ms. | |||||||
Over load protection | code: F03 | The inverter shutdown when output power is overloaded around 120%, it need to be recovered by hand. | |||||||
Over temperature alarm | code: F07 | Buzzer sounds and fault light turns red when the inverter's internal temperature is higher than the limit value (90±5ºC). | |||||||
Over temperature protection | code: F04 | The inverter will automatically return to normal status when the internal temperature drops to 80±5ºC. | |||||||
Short circuit protection | code: F03 | Recover by hand | |||||||
Reverse polarity protection | Built-in fuse | ||||||||
AC input overload protection | code: F09 | The fan will start to work when the relay temperature is up to 60±5ºC; but it will stop to work when the relay temperature drops to 50±5ºC. The unit will alarm, and no AC output when relay temperature is up to 75±5ºC; But it will auto recover when the relay temperature drops to normal value. | |||||||
Fuse | Internal | USB port | 5V, 2.1A | ||||||
Working Temperature | -10°C--+50°C | Production Size | 330x150x78mm | ||||||
Storage Temperature | -30°C--+70°C | Packing Size | 40.5x22x13.5cm | ||||||
Warranty | 18 months | N.W. / G.W. (KG) | 2.6KG/3.2KG | ||||||
Start | Bipolar soft-start | Quantity / Carton | 6pcs | ||||||
Cooling Way | Intelligent cooling fan | Carton Size | 46x42x43cm | ||||||
Certification | CE, E-mark, FCC | Carton Weight | 20.0KG |